Chanitsara Jindarat and Withaya Chanchai*
Volume3-Issue9
Dates: Received: 2022-08-29 | Accepted: 2022-09-21 | Published: 2022-09-30
Pages: 1125-1127
Abstract
The Central Sterile Supply Department (CSSD) is one of the hospital's critical support services. It is a place to receive medical equipment blood-stained from the other departments to be cleaned. It is responsible for cleaning, receiving, storing, sterilizing, and returning medical equipment to everyone and delivered to different departments within the hospital. Nowadays, various cleaning and dissolving blood stains are used to clean and remove blood stains. This research aimed to compare the efficacy of pre-cleaning spray and pre-cleaning spray foam cleaners for blood-contaminated surgical instruments and medical devices in the Central Sterile Services Department. The pre-cleaning spray was significantly higher than the pre-cleaning spray foam (p ≤ .005). A significant difference in the 2-minute pre-cleaning spray was observed by using cleaning indicators. The pre-cleaning spray foam started dissolving blood after 5 minutes. Therefore, from the study, using the pre-cleaning spray for dissolving blood stains and pre-cleaning has a more practical effect than pre-cleaning foam.
FullText HTML
FullText PDF
DOI: 10.37871/jbres1565
Certificate of Publication

Copyright
© 2022 Jindarat C, et al. Distributed under Creative Commons CC-BY 4.0
How to cite this article
Jindarat C, Chanchai W. Comparative Double-Blind Study of Efficacy of Pre-Cleaners for Surgical Instruments and Medical Devices in the Central Sterile Services Department. 2022 Sep 30; 3(9): 1125-1127. doi: 10.37871/jbres1565, Article ID: JBRES1565, Available at: https://www.jelsciences.com/articles/jbres1565.pdf
Subject area(s)
References
- Amrita Shriyan, Ashvij Shriyan. A Study On The Efficiency Of CSSD At A Health Care Centre TJPRC. Journal of Nursing and Patient Safety & Care. 2015;1(2);7-16.
- Rutala WA, Gergen MF, Weber DJ. Efficacy of a washer-disinfector in eliminating healthcare-associated pathogens from surgical instruments. Infect Control Hosp Epidemiol. 2014 Jul;35(7):883-5. doi: 10.1086/676867. Epub 2014 May 20. PMID: 24915220.
- Asima Banu, Subhas GT. Central Sterile Supply Department –Need Of The Hour. J Pub Health Med Res. 2013;1(2):58-62
- Exner M, Bhattacharya S, Gebel J, Goroncy-Bermes P, Hartemann P, Heeg P, Ilschner C, Kramer A, Ling ML, Merkens W, Oltmanns P, Pitten F, Rotter M, Schmithausen RM, Sonntag HG, Steinhauer K, Trautmann M. Chemical disinfection in healthcare settings: critical aspects for the development of global strategies. GMS Hyg Infect Control. 2020 Dec 23;15:Doc36. doi: 10.3205/dgkh000371. PMID: 33520601; PMCID: PMC7818848.
- Kapoor A, Vora A, Nataraj G, Mishra S, Kerkar P, Manjunath CN. Guidance on reuse of cardio-vascular catheters and devices in India: A consensus document. Indian Heart J. 2017 May-Jun;69(3):357-363. doi: 10.1016/j.ihj.2017.04.003. Epub 2017 Apr 13. PMID: 28648434; PMCID: PMC5485387.