Giuseppe Verolino*, Andres Agustin Vecchia, Luca Sandrelli, Mario Fabbrocini and Paolo Cioffi
Volume3-Issue5
Dates: Received: 2022-05-17 | Accepted: 2022-05-23 | Published: 2022-05-24
Pages: 585-587
Abstract
Annular rupture is an ambiguous term that refers to a series of infrequent but life-threatening transcatheter aortic valve replacement complications associated with anatomical and clinical risk factors that often require urgent surgical management. We describe a case of annular rupture following self-expandable valve post-dilatation, successfully treated with urgent surgery.
FullText HTML
FullText PDF
DOI: 10.37871/jbres1483
Certificate of Publication

Copyright
© 2022 Verolino G, et al. Distributed under Creative Commons CC-BY 4.0
How to cite this article
Verolino G, Vecchia AA, Sandrelli L, Fabbrocini M, Cioffi P. Perfect is the Enemy of the Good: Outflow Tract Rupture During Self-Expandable Transcatheter Aortic Valve Implantation. J Biomed Res Environ Sci. 2022 May 23; 3(5): 585-587. doi: 10.37871/jbres1483, Article ID: JBRES1483, Available at: https://www.jelsciences.com/articles/jbres1483.pdf
Subject area(s)
References
- Pineda AM, Harrison JK, Kleiman NS, Rihal CS, Kodali SK, Kirtane AJ, Leon MB, Sherwood MW, Manandhar P, Vemulapalli S, Beohar N. Incidence and outcomes of surgical bailout during TAVR: Insights from the STS/ACC TVT registry. JACC Cardiovasc Interv. 2019 Sep 23;12(18):1751-1764. doi: 10.1016/j.jcin.2019.04.026. PMID: 31537276.
- Barbanti M, Yang TH, Rodès Cabau J, Tamburino C, Wood DA, Jilaihawi H, Blanke P, Makkar RR, Latib A, Colombo A, Tarantini G, Raju R, Binder RK, Nguyen G, Freeman M, Ribeiro HB, Kapadia S, Min J, Feuchtner G, Gurtvich R, Alqoofi F, Pelletier M, Ussia GP, Napodano M, de Brito FS Jr, Kodali S, Norgaard BL, Hansson NC, Pache G, Canovas SJ, Zhang H, Leon MB, Webb JG, Leipsic J. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013 Jul 16;128(3):244-253. doi: 10.1161/CIRCULATIONAHA.113.002947. Epub 2013 Jun 7. PMID: 23748467.
- Moore JW, Laird JR, White CJ, Kirby WC, Ramee SR, Banks AK, Ross TC, Graeber GM, Wahl RC. Tolerance of normal aorta to oversized dual balloon valvuloplasty. Observations in a swine model: technical note. Cardiovasc Intervent Radiol. 1990 Apr-May;13(2):107-110. doi: 10.1007/BF02577363. PMID: 2143690.
- Okuno T, Asami M, Heg D, Lanz J, Praz F, Hagemeyer D, Brugger N, Gräni C, Huber A, Spirito A, Räber L, Stortecky S, Windecker S, Pilgrim T. Impact of left ventricular outflow tract calcification on procedural outcomes after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2020 Aug 10;13(15):1789-1799. doi: 10.1016/j.jcin.2020.04.015. PMID: 32763071.